Wedge Innovations SmartLevel El manual del propietario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 13
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Measuring
with
SmartLevel
Using
Arrow
Symbols
to
Align SmartLevel
Arrows
on the
display indicate which
way to
move
SmartLevel
to
achieve level
or
plumb.
Between
0° and
44.9,°
a
pair
of
arrows
in
opposite corners
of the
display will
point towards
the
level position.
Between
45° and
89.9°
the
arrows will point
towards
plumb.
i
3
c
.9
o
T
The
SmartLevel display electronically "flips
over"
when
the
unit
is
turned upside-down, allowing
for
easy reading when
measuring
overhead components.
Measuring Level
and
Plumb
The
following
table shows
the
display readings
for
each
of
SmartLevel's
four
mode
settings
at
0.0°
45.0°
and
90.0°:
Degrees
%
Slope Pitch
(IN/FT)
Simulated Bubble
Level
0.0° 0.0%
0.0
45.0°
100%
12
Out of
range
Plumb
90.0°
0.0%
0.0
Cl
14
Measuring
with
SmartLevel
Setting
an
Angle
("Zeroing"
Out)
For
some
jobs,
you may
wish
to set a
particular angle
as a
reference point
from
which
you can
take measurements.
For
example,
you may
want
a 3°
surface displayed
as 0° so you
can
measure
all
other angles
from
this benchmark.
A
good
example
is
setting
the
blade angle
on a
radial-arm
saw.
You can
easily
use the
SmartLevel module
to set the
blade even
if
the
saw
table/bed
isn
't
perfectly
level.
Just
"zero"
out the
module
on the
table (set
it to
read
0.0°),
and
then
use the
module
to set the
blade
at the
proper angle
without
having
to
compensate
for the
out-of-level
condition
of
the
saw.
CAUTION:
If you set
your SmartLevel
to
read
0.0°
when
it is off
level,
you
must follow
the
Reset procedure before
you can
once again accurately
read
level
and
plumb
(see
Reset/SuperSet
button,
7-11).
with
Module
Facing
You
How
to Set an
Angle
Place SmartLevel
on the
surface
you
wish
to set at
0.0'
Wait
10
seconds.
Press
the
Reset button
until
the
symbol
"CAL1"
appears,
followed
by the -
angle
measurement itself.
It
will blink
on
the
display.
•Do
not
turn
the
level
180°
as
in the
Reset procedure,
but
instead press
the
Reset
button
again, until
the
sym-
bol
"CAL2"
appears.
That's
it!
When
the
level
is on
this
surface
or
another
at the
same
angle,
it
will read
"0.0°"
To
reset SmartLevel
to
true level
see
pages
7 and 8.
r
>l<
Measuring
with
SmartLevel
15
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13

Comentarios a estos manuales

Sin comentarios