SmartLevel
Maintenance
SmartLevel
is
designed
for the
rugged
construction
environ-
ment,
and the
following
tips
will
ensure
that
your
SmartLevel
is
kept
in top
condition.
The
Sensor
Module
and
rails
are
weather-
and
water-resistant. Should
your
SmartLevel
be
splashed with mortar
or
other construction site
residue,
simply wipe clean with
a
damp cloth.
DO
A/OHMMERSE
THE
SENSOR
MODULE
IN
WATER.
Aluminum surfaces
can be
cleaned with
a
non-abrasive cleansing
powder.
ABS
composite surfaces
should
be
cleaned with
a
mild
liquid soap
and
water.
We
advise
you to
store
your SmartLevel away from extreme temperatures
below
-20°C
(-4°F)
or
higher
than
60°C
(140°F).
Don't forget
to
RESET
your SmartLevel daily,
and to use the
simple
"end-
for-end"
test frequently
to see if
SUPERSET
is
required.
QUESTIONS?
PROBLEMS?
Feel free
to
call
us at
1-800-SMARTLEVEL
(762-7853)
Troubleshooting
Guide
Problem
Reason
Solution
SmartLevel
does
not
turn
on.
Battery dead
or
battery
connections
are not
tight
or
have
become disengaged.
Check
battery connections.
See
Battery,
page
19.
SmartLevel does
not
auto-
matically
shut
off
after
five
minutes.
Sensor
Module
is
being
moved
or
jostled.
Keep
unit stationary
for
five
minutes
or
more;
or
turn mod-
ule off
using
On/Off
button.
SmartLevel does
not
measure
accurately.
SmartLevel
has not
been
re-
calibrated
recently,
or has not
been
recalibrated
correctly.
See
Reset Button, pages
7-11
and
follow appropriate Reset
and
SuperSet steps closely.
Reset
button does
not
work.
Not
pressing
Reset
button
for
a
sufficient time.
Push
Reset
button down
until
the
display reading changes.
See
Reset
Button, pages 7-8.
Difficult
to
select desired
mode
or
range setting.
Mode
or
Hold/Range button
is
being pressed
too
long.
Release
button
as
soon
as
desired
setting appears.
See
Mode Button, page 5-6;
or
Hold/Range
Button,
pages
12-13.
Display
reading "jumps"
or
changes
too
easily.
SmartLevel
is set on a
too-
sensitive range setting.
Use
the
Hold/Range
button
to
set a
less-sensitive range
setting.
See
Hold/Range
Button, pages
12-13.
Display
keeps flashing.
The
Reset
button
has
accidentally been pressed.
Press
the
Reset
button again
or
turn SmartLevel
off.
Repeat
the
Reset
procedure.
Display
reads "ERR"
or
"CAL".
Software
diagnostics code Turn
the
module
off, then
on.
If
display continues
to
read
"ERR"
or
"CAL", replace bat-
tery.
If
display still continues
to
read "ERR"
or
"CAL",
call
SmartLevel
Customer Service
at
1-800-762-7853.
3j';0"
SilCKS
Dirt lodged between
button
and
Sensor
Module
housing.
Hold module with display fac-
ing
downward. Press button
repeatedly
to
dislodge dirt.
Module
slips
out of the
rail. Cams
are not
turned
to
properly lock
the
rail.
See
Transferring
the
Sensor
Module between Rails, pages
17-18,
and
follow
the
steps
closely.
Module cannot
be
removed
or
Cams
are not
properly
difficult
to
remove from rail. positioned.
See
Transferring
the
Sensor
Module between Rails, pages
17-18.
and
follow
the
steps
closely.
Dirt lodged between Sensor
Module
and
rail.
Take
fine-gauge wire
and run
it
between module
and
rail
to
remove
dirt.
Battery
compartment cover Screws
not
completely
does
not
come off. disengaged.
Unscrew more thoroughly.
Follow
procedures
under
Battery,
page
19.
20